Monitor unlimited number of servers
Filter log events
Create email and web-based reports

Direct access to Microsoft articles
Customized keywords for major search engines
Access to premium content

Event ID: 1 Source: RemovableStorageService

Level
Description
Unable to auto-configure library unit Changer0.  The current setup of the library unit does not support automatic configuration.  You will either have to modify the current setup of the library to adhere to automatic configuration guidelines (if possible) or manually configure the device.
Comments
 
Found this to be caused by our Powerloader being setup wrongly for BackupExec. The Powerloader, by default, is set to have the tape drive at a LOWER SCSI ID than the changer (ID 4 - ID6 respectively). Follow Overland Storage Support Document #4151 to fix this problem.
See ME248800 to fix this problem.
Updating the BIOS with the ROMPaq and reinstall the autoloader drivers, seems to have resolved the issue.
See Veritas TechNote IDs: 236992, 234637 and 238760.