Event ID: 1064 Source: StorageAgents

Level
Description
Compaq Drive Array Physical Drive Status Change. The physical drive in slot <value>, port <value>, bay <value> with serial number "<serial>", has a new status of <status>. (Drive status values: 1=other, 2=ok, 3=failed, 4=predictiveFailure).
Comments
 
This error is generated when one of the drives on a Compaq RAID board failed. Check to see if it is firmly inserted and check if the drive is really broken. Sometimes this error is also generated when the backplane of the raid rack is broken.