Monitor unlimited number of servers
Filter log events
Create email and web-based reports

Direct access to Microsoft articles
Customized keywords for major search engines
Access to premium content

Event ID: 2002 Source: Perflib

Source
Level
Description
The Open Procedure for service <service name> in DLL <dll name> has taken longer than the established wait time to complete. There may be a problem with this extensible counter or the service it is collecting data from or the system may have been very busy when this call was attempted.
Comments
 
This error occurs after a reboot of the server because Resource Manger is attempting to query counters of a service(s) that have not yet started. See the link to "Citrix Support Document ID: CTX587401" to solve this problem.
As per Microsoft: "The performance counter provider could not return performance counter data within the specified open timeout period. Either there is a problem with this performance counter provider or the service it is collecting data from, or the system was too busy when this call was made". See MSW2KDB for more details.

Check ME226494 for more details. See the comments regarding the Open Timeout registry value.

Windows Event Log Analysis Splunk App