Event ID: 2124 Source: MSExchangeMTA

Source
Level
Description
Internal Operating System Error, severity 14
(DB Server XFER-IN(12) Proc 98)
Object Data file causing I/O error
Object id 06000091
Operating system error 131
File operation READ
File offset -2133778432
Filename
Referenced object 00000000 (00000000 => N/A)
Referenced object error 0
Comments
 
See ME828255 for a hotfix applicable to Microsoft Exchange 2000 Server.
See ME833879 for a hotfix applicable to Microsoft Exchange Server 2003.

See MSEX2K3DB for additional information on this event.
As per a user suggestion: "You might want to try this:
1. Stop all MTA service on both sites
2. run MTAcheck
3. run MTAcheck /rd /v
4. check for any corrupted DAT file in the MTADATA\MTACHECK.OUT folder and remove them
5. run MTAcheck /rp /v
6. repeat step 4
7. last run MTAcheck once more time.
8. restart MTA service.:
9. Do the same for the other server.
The process I describe above will clean up any corrupted/ghost DAT file in the MTADATA folder".

Check ME174600 and ME235534 for more details on this error.