Monitor unlimited number of servers
Filter log events
Create email and web-based reports

Direct access to Microsoft articles
Customized keywords for major search engines
Access to premium content

Event ID: 24683 Source: CPQCISSE

Source
Level
Description
SCSI bus fault occurred on Storage Box 0 Port 0 of Embedded Controller which may result in a "downshift" in transfer rate for one or more hard drives on the bus.
Comments
 
This issue can also occur in these three cases:

1. After a reboot (Check the Uptime of your server)
2. Conflicts with RILO (Remote Insight Lights Out) (Reset RILO related services)
3. Having an old version of Firmware (Upgrade your Firmware).
The solution from HP Techsupport for HP Smart Array 5i is to uninstall HP Insight Diagnotics using Add/Remove Programs and apply the latest Support Pack (7.30a).
According to HP, this issue affects Smart Array 641/642 controllers, causing drives to unnecessarily downshift to slower speeds. A firmware upgrade to version 2.26c should resolve this issue.
Note: To install this firmware upgrade, you should first upgrade your Smart Array controller to version 5.62.0.32. See the link to “HP Support ID 21465” for additional information on this event.