Logical drive 1 configured on Array Controller in slot 2 returned a fatal error on a read/write request on the volume. Logical block address 5e6b928 block count 128 command 30 drive bus 1 and Drive Id 5.
Comments
 
I got this error in my event viewer along with these:

Event ID: 129
Source: HpCISSs2
Description: Reset to device, \Device\RaidPort0, was issued.

Event ID: 11
Source: disk
Description: The driver detected a controller error on \Device\Harddisk0\DR0

Logged a case with HP and they asked me to run the Array Diagnostic Utility. After running the tool (no downtime is required), the report show this:

SLOT 0 Smart Array E200i Controller ERROR REPORT:
   Array accelerator status:
      Valid data found at reset
      Hardware Problem detected with Cache board.
      Please replace Cache board.

So, it confims that this is due to hardware error on the Cache board and HP is going to replace it for me.
Possibly a damaged drive or controller. Download the latest firmware from Compaq-HP and flash the drive(s) and/or disk controller. If that does not solve the problem, replace the drive to prevent data loss.