The run-time environment has detected an inconsistency in its internal state. This indicates a potential instability in the process that could be caused by the custom components running in the COM+ application, the components they make use of, or other factors. Error in <file>(<line>), hr = <error code>: <function name>.
Comments
 
- Error code: 80040206 - See ME916254.
- Error code: 80070005 - This event may be logged in the event log if the Network Service account does not have the correct permissions. See ME909444 for details on this problem. Also, see Error code 80070005 for details on this error.
We received this error when we tried to call a VB6 com+ in W2K3. The problem was that the Telnet service was disabled. When we switched it to automatic (did not need to be started) everything worked fine.
This event is common in WinXP SP2. Make sure that the service “DCOM Server Process Launcher” is set to "Automatic" mode. Go to Run -> “services.msc”, and set “DCOM Server Process Launcher” to “Automatic”.
Here is the workaround that I use: Open Administrative tools -> Services -> COM+ System Application -> LogOn and change local user into domain user, and start COM+ System Application service.