Event ID: 585 Source: VxSvc_Perc2Pro

Level
Description
PERC 3/Di Controller 0 , SMART:FPT_EXCEEDED on Array Disk 0:0
Comments
 
From Dell's support site (link below):

Cause: A disk on the specified controller has received a SMART alert (predictive failure) indicating that the disk is likely to fail in the near future.

Action: Replace the disk that has received the SMART alert. If the array disk is a member of a non-redundant virtual disk, then back up the data before replacing the disk. Removing an array disk that is included in a non-redundant virtual disk will cause the virtual disk to fail and may cause data loss.