Auto Client Reconnect occurred for user: <user>.
Comments
 
After installing PSE400W2K3R02.0.1 on our PS4 servers, users reported random disconnects. Some users were disconnected once a day and others approximately 20 times per day.
This problem can be identified by enabling logging of successful reconnections in the CMC (Farm settings) then use EventComb to monitor the number of events 9007 on all farm servers.
A support call to Citrix ultimately found that the ICA Listener become corrupt after installing R02.0.1. To fix the problem, delete and recreate the ICA listener. Make sure you check the "use published applications only" checkbox, and then reboot. Use EventComb to verify that the events stopped occurring. Event 9007 is a good thing but excessive numbers of them indicate a problem.