GFI ESM GFI ESM

Event ID: Event Source:

Event ID 12 Source W32Time

Event ID12
Sourcew32time
TypeWarning
DescriptionThe NTP server <server> isn't synced, time not set.
Comments and links for event id 12 from source w32time
 
Event ID12
SourceW32Time
TypeWarning
DescriptionTime Provider NtpClient: This machine is configured to use the domain hierarchy to determine its time source, but it is the PDC emulator for the domain at the root of the forest, so there is no machine above it in the domain hierarchy to use as a time source. It is recommended that you either configure a reliable time service in the root domain, or manually configure the PDC to synchronize with an external time source. Otherwise, this machine will function as the authoritative time source in the domain hierarchy. If an external time source is not configured or used for this computer, you may choose to disable the NtpClient.
Comments and links for event id 12 from source W32Time
 
Contribute
If you have details about an event with id 12 that is not listed in our database, please, send it to us. The submitted event will be forwarded to our consultants for analysis. We recommend you to check the EventID.Net Processing Queue to see if the event was already been submitted by another contributor.