GFI ESM GFI ESM

Event ID: Event Source:

Event ID 9 Source ultra

Event ID9
Sourceultra
TypeError
DescriptionThe device, \Device\Scsi\ultra1, did not respond within the timeout period.
English, please! This information is only available to subscribers. An example of English, please!
Comments Mihai Andrei (Last update 1/18/2006):
This event is common to many controllers. See the link to "EventID 9 from source adpu160m".

Gary Davison (Last update 11/25/2005):
This error may also appear if you use an offboard Ultra ATA controller with a CD-ROM attached, and you insert a CD with autorun enabled.

Adrian Florin Moisei (Last update 5/2/2003):
According to Microsoft "in almost all cases, these messages are being posted due to hardware problems with either the controller or, more likely, a device that is attached to the controller in question. The hardware problems can be associated with poor cabling, incorrect termination or transfer rate settings, lazy or slow device responses to relinquish the SCSI bus, a faulty device, or, in very rare cases, a poorly written device driver." See M154690 link below.
LinksM154690, EventID 9 from source adpu160m
Search Google Web - Microsoft Support - Bing - EventID.Net Queue - More links...
Feedback Send comments - Notify me when updated
 Print version