Event ID: 3006
Event Source: MSExchangeTransport
Event Type: Warning
Event Description: A non-delivery report with a status code of 4.4.7 was generated for recipient rfc822xxxx@xxxxxxxxxxxxxxxx.xxx (Message-ID  <!&!AAAAAAAAAAAuAAAAAAAAAAlVJL34IGROjZKuddd24v8BADegpgUe4PhIvJNtPp/qNeMAAAAAf9UAABAAAABW+Tz0DId4ToVDZ+VGXhGhAQAAAAA=@comcast.net>).  
Cause: Message in queue has expired.  The sending server tried to relay or deliver the message but the action could not be completed before the message expired.    
Solution: This message usually indicates a problem on the receiving server.  Check the validity of recipients address and verify that the receiving server is configured to receive messages correctly.  Resending the message will place it again in the queue if the receiving server is up message delivery will succeed.

For more information see Help and Support Center at http://go.microsoft.com/fwlink/events.asp.
Comment: Message stuck in Local Delivery Queue continually resubmitted for delivery to store (message was from an external user).  message had small attachment
Event ID: 3006
Event Source: Search
Event Type: Error
Event Description: Die Leistungsüberwachung kann für den Gatherer-Dienst nicht initialisiert werden da die Datenquellen nicht geladen sind oder das freigegebene Speicherobjekt nicht geöffnet werden konnte. Dies beeinträchtigt lediglich die Verfügbarkeit der Leistungsindikatoren. Starten Sie den Computer erneut.


- <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
- <System>
  <Provider Name="Microsoft-Windows-Search" Guid="{CA4E628D-8567-4896-AB6B-835B221F373F}" EventSourceName="Windows Search Service" />
  <EventID Qualifiers="49152">3006</EventID>
  <Version>0</Version>
  <Level>2</Level>
  <Task>3</Task>
  <Opcode>0</Opcode>
  <Keywords>0x80000000000000</Keywords>
  <TimeCreated SystemTime="2013-03-16T05:56:48.000000000Z" />
  <EventRecordID>24119</EventRecordID>
  <Correlation />
  <Execution ProcessID="0" ThreadID="0" />
  <Channel>Application</Channel>
  <Computer>HPENVY</Computer>
  <Security />
  </System>
- <EventData>
  <Data Name="ExtraInfo" />
  </EventData>
  </Event>
Comment:
Event ID: 3006
Event Source: Search
Event Type: Error
Event Description: Performance monitoring cannot be initialised for the gatherer service because the counters are not loaded or the shared memory object cannot be opened. This only affects availability of the perfmon counters. Restart the computer.
Comment:

Windows Event Log Analysis Splunk App

Build a great reporting interface using Splunk, one of the leaders in the Security Information and Event Management (SIEM) field, linking the collected Windows events to www.eventid.net.

Read more...

 

Cisco ASA Log Analyzer Splunk App

Obtain enhanced visibility into Cisco ASA firewall logs using the free Firegen for Cisco ASA Splunk App. Take advantage of dashboards built to optimize the threat analysis process.

Read more...